The product has been saved
to your wish list.
Click the symbol on the right on the 'products' button to access the wish list.

KaCool D AF
Heating Cooling Ventilation

Ceiling cassette with AtmosFeel for the highest standards of comfortable air supply and design.

KaCool D AF
Your benefits:
  • Minimalist cassette design

  • Optionally regulated with KaControl, suitable for use with a building management system

  • Whisper-quiet EC technology

Key features

  • AtmosFeel for maximum comfort
  • Draught-free air supply into rooms through side air outlets
  • Discreet cassette design
  • Fully automated KaControl controller or networking with existing external building automation
  • Optionally available with “metal grille panel”, which can be colour-matched to the customer’s requirements

TECHNOLOGY

  • Available in seven sizes
  • Fan units as multi-stage fans or infinitely variable EC fans
  • 2-pipe or 4-pipe system
  • Optional primary air connection
  • 2- or 3-way valves available as accessories, optionally factory-installed in the cassette with larger quantities
  • Integral condensation pump to remove condensation
  • Optionally available with infrared remote control

AREAS OF APPLICATION / INSTALLATION

... also good to know

  • ABS panel with AF (AtmosFeel) in RAL 9010 (pure white)
  • Short delivery times make you fast and flexible
  • Connection option for air outlets provided by the customer
  • Simple installation and maintenance 

 

 

 

More information on cooling

Description

Kampmann cold water cassettes KaCool D AF configured for KaControl control are supplied completely wired and ready for connection with all electrical components fitted. A powerful parameterisable microprocessor provides all of the functions, thus every cold water cassette KaCool D AF has its own "intelligence" and can be operated in groups by means of Kampmann-tLan or CANbus networks.

 

KaControl cold water cassettes KaCool D AF can be fitted with plug-in communications interfaces for single room operation or can also be connected to superordinate BMS systems. Every basic unit therefore has the potential to be integrated within a technical building management system.

Functions

  • Valve actuation for 2-pipe and 4-pipe systems
  • 5-stage fan control with automatic function based on room temperature
  • Temperature detection by KaController
  • Valve activation 24V OPEN/CLOSE
  • Evaluation of condensation alarm
  • Changeover function in 2-pipe systems (heating/cooling) via an external potential-free contact or a clip-on temperature sensor
  • Integration into open BMS systems by optional interface cards (BACnet, Modbus)

System set-up

Control zones with up to 6 cold water cassettes can be connected to a KaController via simple 2-wire bus connection.

 

Control zones with up to 30 cold water cassettes can be connected to a KaController via a CANbus connection.

Prices
Price List 2018download as.pdf, 10,85 MB
Leaflets/Flyers
Spezial KaCool D ceiling cassette, screen-optimizeddownload as.pdf, 1,87 MB
Cross-product information
Product overview, products internationaldownload as.pdf, 5,87 MB
Overview product innovations 2017, products internationaldownload as.pdf, 2,41 MB
Kampmann Hotel Referencesdownload as.pdf, 2,57 MB
Spezial Hoteldownload as.pdf, 2,20 MB
Spezial Hoteldownload as.pdf, 2,41 MB
Spezial retail chainsdownload as.pdf, 3,43 MB
Spezial retail chainsdownload as.pdf, 3,45 MB
Spezial Commercial buildingsdownload as.pdf, 2,72 MB
Spezial Commercial buildingsdownload as.pdf, 2,17 MB
Spezial KaControl building automationdownload as.pdf, 794,90 KB
Spezial Logistics buildingsdownload as.pdf, 830,76 KB
Declarations/Certificates
Interseroh Recycling Certificatedownload as.pdf, 85,22 KB
TÜV Certificate ISO 9001:2008download as.pdf, 140,21 KB
EU Declaration of Conformity KaCool D fan coilsdownload as.pdf, 776,53 KB
CAD drawings
KaCool D AF, 2- and 4-pipe-system, sizes 1-4, grid dimensions 600x600 mm, viewsdownload as.dwg, 400,34 KB.dxf, 3,35 MB.pdf, 101,84 KB
KaCool D AF, 2- and 4-pipe-system, sizes 5-7, grid dimensions 900x900 mm, viewsdownload as.dwg, 516,53 KB.dxf, 4,50 MB.pdf, 117,04 KB
KaCool D, viewsdownload as.dwg, 1,28 MB.dxf, 4,71 MB.pdf, 57,74 KB
Technical details
KaControl recirculating air control accessories

KaController

wall-mounted room control unit, with integral room temperature sensor, only for use with C1 controller
Installation instructions: i385_kurz_kacontroller_int.pdf

Download specifications (.rtf)
Article no.:
196003210001

List price:
174,00 € plus VAT

Room temperature sensor

wall-mounted, surface-mounted, IP30, colour white RAL 9010

Is the KaController installation site suitable for a temperature measurement? - If it is not suitable, e.g. behind a curtain, then a KaControl room temperature sensor should be chosen for each group!
Download specifications (.rtf)
Article no.:
196003250110

List price:
46,00 € plus VAT

Clip-on pipe sensor

for recording the medium temperature, incl. clip-on strap, 3 m cable length, for changeover heating/cooling

Is there a risk of frost, e.g. due to the ingress of cold air – if so, then a KaControl clip-on pipe sensor should be chosen for each unit!
Download specifications (.rtf)
Article no.:
196003250115

List price:
44,00 € plus VAT

Serial CANbus card

For increasing the number of units in a single-circuit system to a maximum of 30 units, one required per unit
For increasing the cable length from the first to the last unit from 30 to 500 m
Download specifications (.rtf)
Article no.:
196003260301

List price:
95,00 € plus VAT

Serial Modbus card

One needed per unit for connecting to KaControl panels or on-site Modbus networks
Download specifications (.rtf)
Article no.:
196003260101

List price:
91,00 € plus VAT
Control accessories electromechanical EC

Room thermostat

230 V, heating/cooling with 2-pipe/4-pipe system, surface-mounted, 3-stage, with OFF/Manual/Automatic fan changeover, max. two units can be connected
Download specifications (.rtf)
Article no.:
196000030155

List price:
175,00 € plus VAT

Clock thermostat

230 V, heating/cooling with 2-pipe/4-pipe system, flush-mounted, continuously variable, with LCD operating menu and integrated timer program, max. two units can be connected
Download specifications (.rtf)
Article no.:
196000030256

List price:
282,00 € plus VAT
Control accessories electromechanical AC

Room thermostat with 3-stage switch

with automatic changeover, surface-mounted, white
Installation instructions: i487_thermostat_148916_gb.pdf

Download specifications (.rtf)
Article no.:
196000148916

List price:
245,00 € plus VAT

Relay box

for the parallel control of max. 4 series 1 units to a room thermostat, only with the electromechanical version in combination with electromechanical thermostats
Download specifications (.rtf)
Article no.:
196000148919

List price:
612,00 € plus VAT
Valve kits

2-way valve kit, open/close

Download specifications (.rtf)
Article no.:
325009012110

List price:
117,00 € plus VAT

3-way valve kit, open/close

Download specifications (.rtf)
Article no.:
325009012120

List price:
125,00 € plus VAT
Panel/grille

RAL 9010 metal panel

The ABS design panel is included with ceiling cassettes with article number 325008XXX001XX. To order these units without design panel, replace the 1 in the article number by a 0 and order the metal panel separately.
Article no.:
325009010020

Price on request
Accessories for KaCool D AF

Supply air connecting spigot

for connection of external air supply
Download specifications (.rtf)
Article no.:
325009020300

List price:
39,00 € plus VAT

 

Hotel Star Inn, Heidelberg

   
   
When are cold water cassettes used for cooling?

Cold water cassettes KaCool D AF are used for air conditioning with recirculating air. They are designed for installation within a suspended ceiling and, when installed, all that is visible is their attractive front panel. Cold water cassettes KaCool D AF are simple to control and operate with water as their environmentally-friendly cooling medium.

In which sizes are the KaCool D AF chiller cassettes available?

The KaCool D AF chiller cassettes are available in two different sizes:

 

  • Sizes 1 to 4 with ceiling panel dimensions of 625 x 625 mm; the suspended ceiling height needs to be 286 mm.
  • Sizes 5 to 7 with ceiling panel dimensions of 900 x 900 mm; the suspended ceiling height needs to be 326 mm.
How are the units maintained?

The filter element fitted to protect the heat exchanger can be simply removed by opening the panel from below. It can be cleaned by rinsing with water or vacuuming. To prevent it from being damaged, the condensation tray should be regularly cleaned by a technician and the condensation pump should be checked.