The product has been saved
to your wish list.
Click the symbol on the right on the 'products' button to access the wish list.

UniLine
Heating

Door air curtains with casings for visible installation.

UniLine
Your benefits:
  • Increased penetration depth by Silent AutoMotion

  • Water and electrical connection protrude out of the top of casing

  • Air curtain and casing form a compact unit

Key features

  • Low investment, top performance
  • Fast delivery service: All sizes of Uniline door air curtains are available ex stock from our warehouse in Lingen (Ems)
  • For controlled screening of cold air with open doors
  • Unit and casing, including top panel, form a compact unit
  • Air screening reduces energy losses and increases comfort in your entrance area
  • Silent AutoMotion: The discharge flap increases the penetration depth of the air stream, particularly at lower fan stages

TECHNOLOGY

  • High-performance radial fans for high air output, wired ready for connection, switchable between 5 stages (AC) or continuously variable (EC)
  • High-performance copper/aluminium heat exchanger
  • Air intake grille opens easily meaning filter can be replaced without the need for tools
  • Easily removable air filter (grade G 2 in line with DIN EN 779); easy to clean by vacuuming or washing
  • Anti-torsion mechanism for heating connections prevents damage to the heat exchanger when screwing in the valves; valves optionally available as accessories

AREAS OF APPLICATION / INSTALLATION

  • Cost-effective design for use in DIY stores, garden centres, showrooms and sales floors
  • Single unit, encased for wall-mounting or ceiling-mounting, free-hanging
  • Lengths 1.0, 1.5, 2.0, 2.5 and 3.0 m
  • Suitable for mounting heights ranging from 2.3 to 3.0 m

... also good to know

  • Lower casing panel, hinged for ease of maintenance
  • The deflection grille in the air outlet ensures minimal turbulence and even air discharge
  • Casing powder coated in RAL 9016 traffic white; air intake grille and outlet air rectifier in RAL 9006 white aluminium
  • KaControl system or electromechanical control possible
  • Integration in KaControl networks or building automation systems, such as BACnet, Modbus or LON possible
Prices
Price List 2018download as.pdf, 10,85 MB
Technical catalogues
UniLine, Cassette UniLine door air curtainsdownload as.pdf, 8,03 MB
Leaflets/Flyers
Spezial UniLine door air curtains, screen-optimizeddownload as.pdf, 2,88 MB
Cross-product information
Product overview, products internationaldownload as.pdf, 5,87 MB
Overview product innovations 2017, products internationaldownload as.pdf, 2,41 MB
Spezial retail chainsdownload as.pdf, 3,43 MB
Spezial retail chainsdownload as.pdf, 3,45 MB
Spezial KaControl building automationdownload as.pdf, 794,90 KB
Spezial Logistics buildingsdownload as.pdf, 830,76 KB
Spezial sports halldownload as.pdf, 2,25 MB
Installation manuals
UniLine door air curtainsdownload as.pdf, 9,99 MB
UniLine - Wiring Diagramsdownload as.pdf, 682,45 KB
KaControl for Door Air Curtainsdownload as.pdf, 2,48 MB
Declarations/Certificates
Interseroh Recycling Certificatedownload as.pdf, 85,22 KB
TÜV Certificate ISO 9001:2008download as.pdf, 140,21 KB
Building product declaration door air curtainsdownload as.pdf, 209,67 KB
EU Declaration of Conformity UniLine, Vario, Tandem door air curtainsdownload as.pdf, 904,60 KB
Data sheet ErP regulation 2016-2281 UniLinedownload as.pdf, 294,25 KB
CAD drawings
UniLine door air curtain, model size 10download as.dwg, 226,44 KB.dxf, 1,99 MB.pdf, 76,66 KB
UniLine door air curtain, model size 15download as.dwg, 247,66 KB.dxf, 2,25 MB.pdf, 83,19 KB
UniLine door air curtain, model size 20download as.dwg, 264,53 KB.dxf, 2,35 MB.pdf, 80,56 KB
UniLine door air curtain, model size 25download as.dwg, 298,69 KB.dxf, 2,69 MB.pdf, 86,76 KB
UniLine door air curtain, model size 30download as.dwg, 349,50 KB.dxf, 2,91 MB.pdf, 87,44 KB
Technical details

This table only gives you a brief overview of the technical data. If you are looking for a more detailed product description and further technical data, please use the technical catalogue. The product configurator and the calculation program will help you to find the right article for your selection.


KaControl recirculating air control accessories

KaController

wall-mounted room control unit, with integral room temperature sensor, only for use with C1 controller
Installation instructions: i385_kurz_kacontroller_int.pdf

Download specifications (.rtf)
Article no.:
196003210001

List price:
174,00 € plus VAT

Room temperature sensor

wall-mounted, surface-mounted, IP30, colour white RAL 9010

Is the KaController installation site suitable for a temperature measurement? - If it is not suitable, e.g. behind a curtain, then a KaControl room temperature sensor should be chosen for each group!
Download specifications (.rtf)
Article no.:
196003250110

List price:
46,00 € plus VAT
Article no.:
196003250114

List price:
26,00 € plus VAT

Serial CANbus card

For increasing the number of units in a single-circuit system to a maximum of 30 units, one required per unit
For increasing the cable length from the first to the last unit from 30 to 500 m
Download specifications (.rtf)
Article no.:
196003260301

List price:
95,00 € plus VAT

Serial Modbus card

One needed per unit for connecting to KaControl panels or on-site Modbus networks
Download specifications (.rtf)
Article no.:
196003260101

List price:
91,00 € plus VAT
Control accessories electromechanical EC

Speed controller

for continuously variable fan speed control, flush-mounted
Download specifications (.rtf)
Article no.:
194000146936

List price:
100,00 € plus VAT

Compact controller

for fan speed control, room temperature control, door contact control and night heating operation, surface-mounted, max. two units can be connected in parallel
Download specifications (.rtf)
Article no.:
196000030158

List price:
195,00 € plus VAT

Surface-mounted frame

for surface-mounted installation of the speed controller, art. no. 194000146936
Download specifications (.rtf)
Article no.:
196000148915

List price:
12,00 € plus VAT
Control accessories electromechanical AC

5-stage switch

Installation instructions: i005_5stufenschalter_100925_100926_gb.pdf

Download specifications (.rtf)
Article no.:
196000100925

List price:
129,00 € plus VAT

5-stage summer/winter switch

Only for use in conjunction with thermoelectric shut-off valve
Installation instructions: i006_5stufensommerwinterschalter_100928_100929_gb.pdf

Download specifications (.rtf)
Article no.:
196000100928

List price:
135,00 € plus VAT

Cascade module

for the parallel operation of two electromechanical door air curtains via one stage switch
Download specifications (.rtf)
Article no.:
196000100906

List price:
248,00 € plus VAT
Valves

Thermoelectric shut-off valve

230 V AC, type 100912
3/4", for KaControl and stage switch!
Download specifications (.rtf)
Article no.:
196000100912

List price:
87,00 € plus VAT

Leaving air temperature limiting valve

3/4", temperature setting range 20 - 50 °C
Download specifications (.rtf)
Article no.:
196000100967

List price:
131,00 € plus VAT
Brackets

Wall brackets

made of sendzimir galvanised steel for wall mounting, powdercoated traffic white RAL 9016
Download specifications (.rtf)
Article no.:
253000500890

List price:
196,00 € plus VAT

Ceiling brackets

made of sendzimir galvanised steel for adjustable suspension from the ceiling, powdercoated traffic white RAL 9016
Download specifications (.rtf)
Article no.:
253000500895

List price:
70,00 € plus VAT
Filter

Replacement filter

1 set = 5 mats
Download specifications (.rtf)
Article no.:
253000510820

List price:
35,00 € plus VAT
WHAT IS SAM - SILENT AUTOMATION?

With the aid of a self-regulating discharge flap in the occupied working area, SAM creates higher air outlet speeds by reducing the outlet cross-section. The flap fully opens at maximum air volume.

 

Depending on the heat requirement on site, open entrances can now be efficiently screened with minimal power consumption and low sound power levels.

 

In extremely adverse conditions and winds, it may be necessary to raise the air volume to maximum load and associated heat output."

How complex is filter replacement?

It is unbelievably simple: the filter can be cleaned and replaced without the need for any tools by unhinging the inlet grille and removing the fixing pin.

Can the heat output from UniLine door air curtains count partially towards the remaining heat requirement in the room?

No, it should not be added to nor be used to meet the nominal heat load in a room. The purpose of a door air curtain is primarily to effectively screen the door opening against the ingress of cold external air.